Ignition status:
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0/0x7E8
SID: 0x22
PID: 0x207E
Start Byte: 3
Byte Length : 1
Start Bit: 1
Bit Length: 1
Example:
7E0 03 22 20 7E 00 00 00 00
7E8 04 62 20 7E 02 AA AA AA
*****************************************************************************************
Ignition (Second Source)
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0/0x7E8
SID: 0x22
PID: 0x20D0
Start Byte: 3
Byte Length : 1
Start Bit: 6
Bit Length: 1
Example:
7E0 03 22 20 D0 00 00 00 00
7E8 04 62 20 D0 C0 AA AA AA
*****************************************************************************************
Ignition (Third Source)
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7EA / 0x772
SID: 0x22
PID: 0x20D0
Start Byte: 3
Byte Length : 1
Start Bit: 6
Bit Length: 1
Example:
7EA 03 22 20 D0 00 00 00 00
772 04 62 20 D0 C0 AA AA AA
*****************************************************************************************
Engine Runtime
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0 / 0x7E8
SID: 0x22
PID: 0x001F
Start Byte: 3
Byte Length : 2
Start Bit: 0
Bit Length: 0
Units: Seconds
Example:
7E0 03 22 00 1F 00 00 00 00
7E8 05 62 00 1F 01 55 AA AA
*****************************************************************************************
Oil Life Remaining
Protocol: GMLAN
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0 / 0x7E8
SID: 0x1A
PID: 0x6D
Start Byte: 3
Byte Length : 1
Start Bit: 0
Bit Length: 0
Example:
7E0 02 1A 6D 00 00 00 00 00
7E8 03 5A 6D BB AA AA AA AA
0xBB = 187
187 x 100 / 255 = 73.33%
*****************************************************************************************
Odometer:
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0 / 0x7E8
SID: 0x22
PID: 0x00A6
Start Byte: 3
Byte Length : 4
Start Bit: 0
Bit Length: 0
Units: KM
Example:
7E0 03 22 00 A6 00 00 00 00
7E8 07 62 00 A6 00 1F 95 EF
0x1F95EF = 2069999 KM
2069999KM = 128,623 Miles
***** NOTE **** This vehicle supports Classic OBD Odometer using Mode 01 PID A6
*****************************************************************************************
Fuel Level
Protocol: UDS
OBD PINs: 6/14
Bus Speed: 500 kbps
CAN IDs: 0x7E0 / 0x7E8
SID: 0x22
PID: 0x002F
Start Byte: 3
Byte Length : 1
Start Bit: 0
Bit Length: 0
Units: %
Example:
7E0 03 22 00 2F 00 00 00 00
7E8 07 62 00 2F 80 AA AA AA AA
0x80 = 128
128 x 100 / 255 = 50.2 %
***** NOTE **** This vehicle supports Classic OBD Fuel Level using Mode 01 PID 2F
*****************************************************************************************